ERR_WIS_30272 Maximum character output size limit reached in Bind Export tasks
Symptom
Bind Export tasks with Webi documents exported with the XML format end up in warning/failed state with the following error:
Error: com.businessobjects.sdk.core.server.CommunicationException$UnexpectedServerException: Maximum character output size limit reached. Contact your BusinessObjects administrator. (Error: ERR_WIS_30272)
Environment
- 360Suite Legacy
- SAP BusinessObjects Business Intelligence 3.1
- SAP BusinessObjects Business Intelligence 4.1
- SAP BusinessObjects Business Intelligence 4.2
Reproducing the issue
- Log into 360Suite Legacy 360Bind.
- Schedule a Bind Export task for a large Webi document, using the XML format.
- Open the logs of the task.
Cause
The XML files exported by the task using the SAP Business Objects SDK are too large for the WebIntelligenceProcessingSever servers.
Resolution
- In the CMC, go to Servers > Servers list > Properties of your WebIntelligenceProcessingServer servers.
- Under the "Web Intelligence Common Services" section, increase the parameters below.
- Restart the updated servers
- Maximum Character Stream Size (MB)
- Binary Stream Maximum Size (MB)
Keywords
360bind, Webi, binary, stream, size, character, output, limit, reached, ERR_WIS_30272
Product
Product or Product version
- 360Bind
Languages
- English US
- English UK
- French
Last updated about 5 years ago